Programming a DAS

Programming a Q330 with Hocus

Q330 Lab Bench Testing

 

 

First Part of Q330 SET-UP.

 

***Disable Internet LAN connection 1 and Enable LAN connection 2.

 

Connect Ethernet cables to Qnet connection on Q330.

Run Hocus.

Enumerate. Refer to Figure 1. Note: if any Q330s will not enum., check IP/FW using Willard.

Programming a Q330 with Willard

Willard is Quanterra's program to program and control Q330's. It is a standalone Windows program which allows you to set parameters, monitor data acquisition, storage, gps power cycling, sensor control, and much more. It is a very powerful and complex program which does not lend itself to a brief 'walkthrough' via a webpage.

Due to its complexity and ability to control every aspect of a Q330, it is very easy to make a severe mistake which would make the Q330 not function as intended. We highly recommend that only experienced users of Willard program Q330 parameters. You should contact a EPIC staff member if you have any questions regarding using Willard to program a Q330.

During training at EPIC, users receive a walkthrough of Willard.

 

Programming a Q330 with a Clie

To program a Q330 with a Clié you need to use either the "Q330 B147" or "Q330 1.491t" program. These programs can be found on the main menu of any Clié received from EPIC. These programs are used to send or retrieve parameters/configurations, change station names, change IP addresses, and to send commands to a Q330.

Important note: To program a Q330S (which is different from a normal Q330) you MUST use the program "Q330 1.491t"

Syndicate content